This video got me to thinking how serious an issue a thermal runaway of a camper van LFP battery can be. The runaway produces toxic and flammable gases that can result in a fire that is difficult to put out and even an explosion can also result. In this case, the only way the firefighters could effectively handle the fire was to cut the cables to the batteries and (wearing breathing equipment) remove the batteries from the RV. In my van the batteries would not be so easily removed and I don’t have the equipment or training to do it.
In thinking about this I wondered if enclosing the LFP battery in a sealed and heat resistant box that is vented to the outside might be a way to handle this.
This is a report on a test of a prototype of this sealed box solution to see if it might actually work.
I want to make it clear that I’m not to the point of recommending the box as the solution – I’m just passing on data and hoping for some good comments.

One of the cells in the LFP battery at the peak of its gas output.
What is it? How does it work? Why?
It is a box made with plywood and lined with fire resistant concrete board that encloses the house battery on a camper van. The box is sealed but has a pipe that vents toxic gases produced in the case of a thermal runaway of the LFP battery to the outside. This hopefully keeps the occupants from being exposed to high concentrations of very toxic gasses, and prevents a fire or explosion inside the van.

Background
I’m not saying there is enough good information available yet to decide if its a good idea to adopt this solution of enclosing the house battery yet. The way I see it now…
The dangers with LFP batteries if they do go into runaway while you are sharing the same van space:
- Toxic gasses: When the vent cap on an LFP cell blows, a lot of very toxic opaque gas will be rapidly released and fill the van. The gas from LFP cells in runaway is about 12% CO – very deadly.
There may be very little advance warning that the runaway is about to occur. - Explosion: The LFP main gasses are very flammable H2 and CO. If they make the right mixture with the air in the van and there is an ignition source there will be an explosion. Other Li battery chemistries runaway gasses include oxygen so the runaway heat will likely result in a fire right away – LFP batteries do not generate oxygen, so there is more chance that the van will get to an explosive mixture. Two of the examples listed below are explosions.
- Fire: The runaway gasses are quite flammable and if there is an ignition source and the mix is not explosive, then it will burn. Once in runaway the cell will continue to produce gases until until the cell materials are exhausted – it is a fire that is challenging even for professional firefighters to put out.
- Loss of Van: Your van may burn down. You can’t just point your regular ABC extinguisher at an Li battery fire and put it out. In the example below the firefighters wearing breathing equipment had to cut the battery cables and pull the batteries out of the RV. Without firefighter equipment and training there is not a lot you can do.
The part of the whole problem that is most in doubt to me is whether the risk that an LFP will go into runaway is so low that its not worth taking precaution of building the containment box. LFP cells are less likely to go into runaway than other Li chemistries, but, there are many ways it can happen: over charging, over discharging, BMS failure with overheat, external heat (eg bad connection), cold temperature charging, manufacturing defects… There are a few examples listed below, but I’ve not been able to find many. I suppose more data on this will come in with time as more batteries are installed and they age.
After seeing example 1 below, it occurred to me that the only way firefighters were able to get the situation under control and save the RV was to get the batteries out of the RV. I could not do that the way my batteries are installed and I don’t have the equipment or training to do it safely. In thinking about it, it occurred to me that maybe enclosing the battery in a heat resistant sealed container that is vented to the outside might address all the dangers in the list above. Lots of variables, like what are the inside pressures and temperatures going to be and what kind of flow through the vent, and would the box be able to stand all this while cell after cell went into runaway, but it seemed pretty easy to do a simple test of a simple box and just see, and I like doing tests!
Examples:
- Vanlife Youtube couple has LFP fire in their RV…
- Another Vanlife Youtube couple has LFP fire in their RV..
- Boat with RV like LFP battery system explodes – From Stached site…
- Closed room with LFP batteries explosion – From Stached site…
The Stached site… has a number of good videos on LFP battery
Will Prowse on LFP explosion hazard…
Some testing of various brands of LFP batteries at runaway…
There are also quite a few golf cart based fires and explosions. While the stores often don’t say what chemistry the battery was, but almost all electric golf carts use LFP batteries.
If you know of other LFP battery events, please let me know. I suspect there are a lot more, but most are not reported widely – note that the first two RV examples above just happened to be people who had Youtube channels on their RV adventures, otherwise we would probably never heard about their LFP incidents.
Construction
The box encloses the LiFePo4 house battery in a sealed and heat resistant box that is vented to the outside. It may protect the van and occupants from the toxic gases, fire and explosion hazards of a thermal runaway of the battery. This prototype is a first cut at testing the idea.

Box
The prototype battery enclosure is a box made with plywood and lined with Hardie Backerboard. The top is removable to allow the battery to be installed or removed. A 1 inch vent pipe vents gas resulting from a thermal runaway to the outside. Any wires going in or out of the box need to be sealed to prevent gas release. I left a bit over 1 inch clearance between the box and the battery on the sides and top.
The box is made from half inch MDO plywood, but any descent plywood should work – I used the MDO because I had it on hand. The joint design allows for good glue area and a box that can resist a significant amount of internal pressure.

This shows the wall construction. The overlap joints with glue blocks are meant to provide some resistance to internal pressure.

Showing blocks added to top edges to fasten the removable lid to.
The lid has to seal to the box to keep gas from leaking out. I attempted to do this by providing the blocks along the tops of the sides and sanding this smooth, and then running a bead of silicone along the blocks to form a sort of rubber bulb seal. This did not work well in that it leaked some gas during the test. Some other form of seal that seals better but still allows the lid to be removed is needed – perhaps a foam gasket.
Quarter inch Hardie Backerboard is used to line the inside of the box. This material has a one hour fire rating and holds up to the blow torch test well. Its also cheap.

Hardie backer board with a propane torch – this could go on for minutes and is far in excess of what it would see in an LFP runaway.
Hardie Backerboard pieces were cut to fit the inside of the box and the lid and secured in place with silicone caulk (silicone caulk has a good maximum temperature capability).
The Hardie Backerboard is easy to work with and cuts by scoring with a utility knife.

The box with Hardie Backerboard installed. Sanding the top surface to make a smooth surface to seal better.
In the test, the maximum inside surface container temperature was about 350F and there was no burning, so there may be a simpler way than using the Hardi Backerboard to protect the plywood? But, it did do well in the test.
The lid is screwed down with an abundance of screws to withstand internal pressure better and to seal better.

Follow
Vent
When a cell goes into runaway and blows its pressure relief cap, a lot of gas is released in a short time . The vent pipe would exhaust these toxic gas through the van sidewall or floor.
The vent tube is a 1 inch copper pipe. A vent pipe that is too small might result in an internal box pressure that is too high for the box. I could not find a good way to size the diameter, and picked the 1 inch as a guess. In practice it seems to work well. The choice of copper is just because I had it on hand – any metal tube would likely work.
The maximum vent tube temperature during the test was about 250F – this probably means that a metal tube is needed. This stainless steel flexible pipe might work.

The vent tube is simply glued in place with urethane glue in a snug fitting hole in a thickened part of a wall – very solid.
The finished box

Not to pretty, but functional.
The pressure sensors and thermocouples have been installed at this point. The holes I forgot to seal with silicone did leak some gas during the test. The holes sealed with silicone caulk did not leak any gas.
I paid quite a bit of attention making the box able to hold up to significant internal pressure, but the test did not seem to result in much internal pressure, so a more relaxed approach may be OK?
The Battery Setup
This section goes over how the LFP battery was setup for the test.
The battery for the test was a new Dumfume 150 amp-hr, 12 volt LiFePo4 (LFP) battery.


The battery with top cut back. Four cells in series to make 12.8 volts. Generally it seems made OK , but I’m sure Will P. would like the BMS held in place more securely.
The BMS is on top and there is very little clearance between the cells and the plastic case. I had hoped to cut the top back, pull the cell pack out and install the heater, and then glue the top back on, but there was just not enough clearance to do this and the test was done without the lower part of the case. I doubt if this made much difference as the plastic cover was basically melted into a puddle from the high temps inside the case due to the runaway.

This shows how the cells were compressed togehter. On each end of the cell stack is a substantial steel plate. Three plastic bands are used to wrap around the cell stack and steel plates to compress things together. In this picture I am cutting the middle strap in order to make a place to mount the heater used to induce runaway in the end cell. By the end of the test there was no trace at all of the two remaining straps.
Heater
In order to test the battery enclosure idea, its necessary to induce a thermal runaway. Even though LFP batteres are resistant to thermal runaway more than other Li chemistries, there are lots of ways it can happen: overcharging, over discharging, BMS failure with overheat, external heat, charging when too cold, manufacturing defects, … But, to purposely cause a runaway, the most common methods are to force a sharp object into the battery cell, or to apply heat to a cell. I was going to use the projectile method in that it is simple and in most cases results in a solid runaway, but in the end I picked the heater method as it seems closer to the real world causes of runaway and I was able to find good and rugged heater that did not cost an arm and a leg – the heater method also let me keep more distance from the bad things that happen with a runaway.
By the way, you see a lot of Youtube videos of people penetrating LFP cells with sharp objects and there are no consequences. I believe that this largely is a result of doing the tests with a battery that is not at or near full charge. An example of several brands of battery cells penetrated that do show significant gas release.
For our test, the battery fully charged.
To apply sufficient heat to the first cell in the stack to generate a thermal runaway, a 500 watt stainless steel strip heater was clamped onto the outside of the steel plate on the end of the cell stackup. So, the steel plate distributes heat into the cell.

This shows the heater clamped to the steel plate compresses the cell stack. I scrapped the paint off the steel plate for better thermal contact.

Closer view of the heater. The white stuff is a Boron Nitride high temperature thermally conductive coating to increase the heat transfer from heater to cell stack. This proved to be a pretty tough heater – it still worked after the test even though it was subjected to 800F + temps and was bent into a curved shape by the cell bulging out.

Picture of battery with heater in the enclosure box. Note that the top of the battery case is in place, but the lower part of battery case is missing because it did not have enough room for the heater and heater clamp.
Instruments
Temperature:
Several thermocouples were added to the setup to log temperatures during the test:
- TC1 – On the side of the cell 1 (which has the heater) and about 1 inch above the heater (close to place heat was being applied) – nearly the hottest location on the cell?
- TC2 – On the top of the cell 1 (which has the heater). A location as far from heater as possible but still on this cell – nearly the coolest location on the cell?
- TC3 – Inside the enclosure about an inch down from the lid on the hot end (heater end) of the enclosure (aiming for the hottest part of the box)
- TC4 – On the outside of the vent tube near the box (probably a few degrees less than the exhaust gas temp and lagging a bit behind it)
I had intended to log a couple more locations, but my 2nd thermocouple logger stopped working – but the logged ones give a pretty good picture.
Pressure:
It seems like the pressure that the enclosure has to withstand is a key thing, so I tried to get a good reading on it two ways.
The simple one is a simple analog pressure gauge. The regular dial indicates the current pressure and the 2nd dial (called a “lazy hand”) rides along with the regular dial, but stays at the highest point it gets to – so it records the maximum pressure. This screwed into the lid and is placed such that it can be read in the video.

The other pressure sensor puts out a voltage that is proportional to the pressure that can be logged.

While neither pressure measurement method worked exactly as intended, both indicated that enclosure pressure remained relatively low throughout the thermal runaway event. This was surprising.
I would like to have also logged the flow rate out the exhaust vent and the total volume of gas exhausted, but could not figure out a simple way to do this – if you have any ideas, please let me know.
Follow up Pressure Test: 11/3/26
I did some follow up testing of the box to see if I could seal up the air leaks that allowed some smoke to leak out between the box lid and the box and small leaks in a few other places. I also got a pressure gauge with a smaller range to better match the pressure during the test ( 0 to 10 psi) and tested it as well. The air source was a compressor.
To seal the lid on better, I belt sanded the top of the box smoother, and then used the foam tape in the picture below as a gasket between the lid and the box. The foam tape has an adhesive on one side. The foam tape worked well, with no apparent leakage. I also sealed up some small holes with screws and bolts and added a thicker layer of caulk at all the corners.
This results in a box that hold pressure well.

This is the foam tape. It is 1/4 inch thick and 1/2 inch wide and compressible. The lid screws compressed it down quite a bit – maybe to 1/16th inch. This was just something I had in the junk box, but it seems like a pretty good solution – maybe go a bit wider?
The new pressure gauge is the same design as the one used in the test, but its 0 to 10 psi rather than 0 to 100 psi.

The new gauge. 0 to 10 psi. The black hand registers the current pressure and the red hand stays at the maximum pressure achieved.
Pressure test to failure:
I ran the pressure up until the box failed. This happened at about 10 psi.

The picture shows the failure. These were glued joints and the failure appears to have occured in the plywood rather than in the glue. I just used 16 ga nail gun nails to hold the joints while the glue dried. Using screws might get a higher failure pressure, but given that the max pressure during the test was 1 psi ish, this construction is probably OK. The failure was not gradual – more of a bang.
Test Results
Key test takeaways:
| All four cells progressed into thermal runaway |
| There were calm times between successive cell runaways |
| A substantial volume of toxic/flammable gas was vented for each cell |
| The enclosure remained structurally intact for the full event |
| The 1 inch vent tube had enough capacity to do the job |
| Peak cell surface temperature reached 800F |
| Peak enclosure wall temperature reached 350F |
| Peak vent temperature reached 290F |
| Total event time exceeded 2.5 hours |
| There were periods with no gas venting between successive cell runaways |
There are 4 cells in series that make up the 12 volt battery. In this test all of the four cells went into runaway one at a time.
Cell 1 is the first cell and has the heater clamped to it to induce runaway. The heater heats up the cell, and when it gets hot enough it will go into thermal runaway. Once the thermal runaway chemical reactions start, they generate their own heat and basically won’t stop until all of the materials in the cell have been used up.
In the case of LFP cells, the runaway reaction does not generate any oxygen, so oxygen for any fire has to come from outside. But, the gasses produced include a lot of H2 and a lot of CO, which are both flammable. So, given that this is a closed box, I was not expecting any fire or explosion inside the box as there is no oxygen, and this did prove to be the case.

The test did get a good thermal runaway that in the end got to all 4 cells.
There was a significant amount of toxic/flammable gas flow out the vent.
The battery enclosure box survived the full four cell runaway with no significant damage – it could be cleaned up and used for another test.
Temperature logs:

Thermocouple temperature sensors:
TC1 Red – Installed on the side of the cell with the heater and about 1 inch above the heater.
TC2 Yellow-Green – Installed on the top of the cell with the heater
TC3 Blue – Installed on wall of the box on the end with the heated cell. Should be near the hottest part of box.
TC4 Aqua – Installed on the outside of the vent pipe near the box.
Notes:
TC1 near the heated part of cell 1 rises rapidly as soon as the heater is turned on at 3:18 pm.
Its hard to say exactly where the runaway on cell1 starts, but probably around 4:00 pm where the temperature starts rising more rapidly. The vent plug blows at 4:40 pm. TC1 drops briefly presumably due to the cooling effect of the vented gas. The heater is turned off at this point, so all further temperature rise is due entirely to the runaway reaction.
TC1 continues to rise and reaches and impressive 800F for a short time.
Note that the other cells probably reached similar temps as they went into runaway, but I did not have thermocouples on them.
TC2 (top of runaway cell) follow the same general timeline as TC1, and got up to about 520F.
TC4 (vent pipe temp) increases rapidly due to the hot venting gas, and reaches 250F for this cell. The actual gas temp is probably a few degrees higher as the thermocouple is mounted to the outside of the copper vent pipe.
TC4 shows peaks for each of the 4 cells going into runaway. The thermocouple TC4 may have been failing by the time of the 4th (last) cell going into runaway.
Since I did not have thermocouples on the other three cells to directly show when they went into runaway, the easiest place to tell is the TC4 vent temperature, which peaks up the start of each runaway. The maximum it reaches is about 290F.
TC3 (box temp) rises to about 280F for this first cell runaway. It continues to rise as the other cells go into runaway and reaches a maximum temp of about 350F about 2.5 hours into the test, and then starts to slowly cool off. This is something to consider when designing a box – it has to be good for the first cell runaway, but it also has to hang in there as other cells go into runaway and temps continue to rise.
Note that this is not a short event – from the time the first runaway starts until temperatures drop below 400F is about 2.5 hours, and some temps are still at 300F 5 hours after the start. Any kind of solution needs to deal with this long time span.
The picture above shows venting at its maximum – this lasts for about 2 minutes as each cell goes into runaway, and then continues at lesser volume and then goes down to almost nothing as a cell runaway fizzles out. I watched the first cell go and fizzle down and thought the show was over and went in the house for a cup of coffee – by the time I came back out, it was going gang busters again. There is a message in this if this happens to you – don’t be too quick to declare the issue over!
At one point when the gas flow was not to extreme, I did light the gas with a butane torch and it burned impressively. I got a picture of it, but can’t find it. What would happen in a van situation if the gas flow as in the picture above was lighted is something to think about.
Timeline:
Here are some pictures along the timeline of the test…
First 51 minutes – boring
The first 51 minutes of the test looked just like the picture below – other than the logger reporting temperature increases there was really no action – no smoke or noises.
If actual events go this way (which is what the examples seem to indicate) there won’t be any warning before the runaway.
The exception was that at 33 minutes there was a snap sound that was accompanied by a bump in the TC1 temperature. It was not very loud and I would not have heard it if I was not sitting close by. But, no idea what it actually was?

4:19 pm, 51 minutes in the Vent plug on cell 1 blows. Venting of gas starts –

The first cell blew its vent plug and the vent started to emit smoke which grew rapidly in volume. At full vent it looks like the picture below. Its pretty impressive. I was thinking maybe I should be further from the shed in case this catches on fire!
Note that on one side of the lid there is a leak that would be leaking toxid gas into the van – a better seal between the lid and box is needed.

This goes on for about 10 minutes and then fizzles down to near zero before the next goes into runaway. The vent outlet temperature (TC4) shows the timing pretty well.
After the first cell blew and went through the impressive gas emission and then fizzled to nothing, I thougt the show was over and went to get a cup of coffee. When I came back out, the 2nd cell had gone runaway and the smoke was going gang busters. This is something to remember if you have one of these events – there are multiple cells in the your LFP battery and the 2nd, 3rd and 4th cell may still blow after the first cell has settled down.
Aftermath:
These are some pictures of what the box and the battery looked like after the test.
The vent pipe after test. The inside of the pipe was also black stained.

Looking down into the box at top of battery.
The BMS is inside that blob of melted plastic.

This is the vent pipe exiting the box.
I wonder what marks leading down are – looks like a liquid draining down?

Top of the battery showing the four blown vent plugs.

Looking down into box after battery was removed.

The thermocouples took a beating, but for the most part kept working.

Shows the heater after test. Note how the very stiff stainless steel heat was bent into
a curve as the LFP cell bulged.
After taking the heater off and banging it back straight with a hammer, I hooked it up and it still works.

Cutting the aluminum busbars with a Sawzall to separate the cells.
I gather that the black gooey material comes from inside the cells?

This is one of the steel plates used on each end of the cell stack as part of
system to keep the cells compressed.

The bulged out cell 1 after test.
While all of the cells were bulged to some degree, all of them retained their basic shape and did
not develop any apparent breaks other than the vent plugs blowing.

The top of the box after test.
The Hardi Backerboard is stained, but appears undamaged.
Removing the Hardi Backerboard in a couple of the hotter locations to look at the plywood
showed no damage or even discoloration of the plywood.

Other Things to Do
Short of building an enclosure box, these things might be helpful in the case of a runaway.
In the build up to full runaway and the vent plug blowing, there will probably a steady rise in temperature. So, one way to get some warning is to install a temperature sensor on the battery that has an alarm that goes off when the temperature increases beyond a point. I think this should be pretty effective as the temperature rise on the way up to runaway is quite large. This is a good thing to do even if you do build the box.
Smoke detectors will also work, but you won’t get any warning until runaway actually starts, but it might wake you up at 2 am and give you time to get out.
Depending on how your battery is setup, it might be possible to work out a way to get the battery out of the van, which might save the van. A set of heavy duty cable cutters to quickly cut the cables, and a way to undo or cut the straps holding the batteries down. And, some ropes attached to the battery so you can drag it out without getting so close to the runaway battery. Hopefully the temperature alarm lets you do this before the vent caps blow and before the smoke. BUT, if there is already smoke, you should just concentrate on getting out.
Just having a plan for what to do when the battery wakes you up a 2am is a good thing to have.
Any other ideas?
Safety
If you decide to do some testing of your own (and I hope you will), please be careful. I tried to be careful: I did the test outside away from flammable items, wet down the ground before, did it on a day with some wind so I could position myself upwind, had buckets of water and a hose nearby, positioned myself several feet upwind and wore real clothing, glasses and gloves.
You are dealing with very toxic gases that are also very flammable – be careful.
If you see other precautions I should have taken, please say so in the comments.
Comments:
Well, congratulations on getting all the way down here!
I am very much interested in an comments or suggestions anyone might have on the test as well as ons the concept of using a vented box to handle LFP runaway events.
Gary 10/12/26
Thanks Gary for this great test! It certainly makes a case for the value of an enclosed box with a vent to the outside.
The box would need at least two holes for the positive and negative cables. Is silicon the best type of caulking to seal up the holes? I wonder about butyl tape? The vent pipe would need a screen to keep insects from “camping out” in the battery box.